Generic selectors
Exact matches only
Search in title
Search in content
Post Type Selectors

Reply To: Quintum 800

#23123
ds
Guest

Greetings!! I need help to configure a TENOR A800, Actually I´ve never worked with one of this before!! so it´s my first time, The Radius and IVR are working find, but I do not know how I configure to redirect PSTN CALLS to the Net and, How I do to let know remotes to know how to reach the Quintum, actually it´s my first tyme on VoIP technology so I would Apreciate any help!!

Solution: Do not register the remote/changing gateways to the gatekeeper. Instead, point the remote gateways to the border element of the one that is on a static I.P. address.
Advantages: 1)There is no limit on the ammount of gateways that you send information to a border element.
2)Seems to work a lot better, specially whent the remote gateways are on PPOE.(Do not ask why, I do not know, I just noticed it).

I have three gateways working that way right now, and I am impresed. Not a single one of them failed to report to the border element after a change of I.P. address in over a week!!!!!

I never saw any of my quintums on remote sites go this long without a need for a reset or power down.

in order to see the I.P. of the remotes, go to the prompt and type :
gk table.

Go to the remote gateways and put the I.P. of the “master” or gateway on static I.P. address under “border element 0”

Do not enter anything on the gatekeeper field of the remotes.

Warning: By these settings, the remotes will “learn” the static I.P. routes of the master, and try to contact them directly. If you have static routes defined on the gateway that you are using as a border element, the remotes will “learn” the routes.