you can use parameter CCCH from 1 to max 4.
Multiple CCCH is used in order to increase paging capacity in cells. Multiple
CCCH means that up to 4 time slots can be configured with CCCH blocks. The
new CCCH channels shall be configured on TN2, TN4 and TN6 on the BCCH