We require minimum 24 Idle TS in any cell with 3 sectors if we have defined 2 Static PDCH in each sector.

2 Static PDCH * 3 sector =6 (64 K TS)

6 (64K)= 24 (16k) Idle TS

This is kept for providing min service to one subscriber given he only gets Static PDCH.