18th August 2010 at 14:03
#64030
Guest
Hi Jacubs,
– When changing the PMU ensure the right setting of the DIP switch.
– Check also, if you use M2000, the ressource of BTS (Site maintenance system-View ressources-DC voltage and AC voltage)
– conform the installed PSUs and the configured PSUs (modify site card parameter-double click on DPMU board)
Regards,
NJ