28th July 2010 at 07:55
#63818
Guest
Hi RK,
I have only answer on part of your questions:
1- for BW, 9TRXs= 1152 without EDGE, 1920kbps with EDGE (minimum value)
2- for TS SYNC alarm:
– Manually block the fault-suspected TS: command RXBLI.
– Test the fault-suspected TS: use command RXTEI.
– If test result doesn’t indicate a fault in the TS, Perform a loop test: use command RXLTI.
– If loop test is successful, manually deblock the fault-suspected MO: use command RXBLE.
– If test result indicates a fault in the TS or loop test failed check the E1 TRC side.