AKKI
Guest

Dear Neraj,

To reset the TG/CF/TRX/TS –

RXBLI:MO=RXOCF-202,SUBORD,FORCE;
RXESE:MO=RXOCF-157,SUBORD;
RXESI:MO=RXOCF-157,SUBORD;
RXBLE:MO=RXOCF-202,SUBORD;
**********************************
RXBLI:MO=RXOTRX-94-1,SUBORD,FORCE;
RXESE:MO=RXOTRX-157,SUBORD;
RXESI:MO=RXOTRX-157,SUBORD;
RXBLE:MO=RXOTRX-94-1,SUBORD;

In case of TS,just remove the SUBORD.