#45920
Pix
Guest

hi rf learner,

Reports of distance… you mean the measurements reports with the timing advance information ? i’m not sure what you mean here. mmm… maybe, you can decide to limit the coverage of your cell, so only subscribers with a high level (and therefore a “clean” signal) are able to connect to your cell.

for instance, set the rxlev access min to -85dBm. that will not prevent the interference to happen but it will prevent your subscribers to be subject to it.

and what are the results of the frequency scan ? all 124 channels are used ?
what about discussing it with the other operator ?

in my opinion, in such a case where you can’t control the interferer, you can only do one thing : change your own frequencies. There is nothing else you can “play around” with. But maybe i missed something..