Tom
Guest

Hi Teodor,

Yes, you may be right. I may have configured something wrong. But, what pointed me to the pulse-duration problem was these entries in the event log when an incoming call clears:

cas |01/01| 2000/01/01|00:05:54:570 |Received Message

CAS: HL Message

CAS: ABCHANGE Message

[2,0,2,1] Process AB change: ABCD=0xf.

[2,1]CasCall::abChange: ** CasState=7,ABCD=0xf

HL Event = 6

[2,1] casProc: Disc-Idle for incoming call

[2,1] Start Timeout, ID = 16

[2,1] New State = 8

cas |01/01| 2000/01/01|00:05:55:070 |Timeout Event = 16

Stopped Timeout T = 16

[2,1] casProc: x4-T16

[2,1] casProc: x4-T16, Current/Voltage (34/248)

[2,1] casProc: Flash event occured, State = 8

casProc: Far-End Disconnect pulse < 600mS, ignored... [2,1] New State = 7 I have already raised this with Techland. I'll post the result here.