16th July 2004 at 16:07
#27634
Guest
You should review the documents Quintum has about disconnect supervision and answer supervision. You cannot have the cassig set to 5 and supervision set to 3. This is not correct. First, for the reverse battery does your GSM device provide reverse battery to the Quintum? Based on your description, I am betting not. Set the cassig to 1 and re-test.