i will discribe on motorola standards,
to make faster or slower cell reselection, note the following formula:
C2 = C1 + cell reselect offset – H * temp offset
where H = 1 when T < penalty time.
and H = 0 when T > penalty time.
note: T: the time in which the UE is located under the cell in seconds.
and the equation is
C2 = C1 – cell reselect offset
when penalty time is set to 31
you can optimize the parameters as you wish but keep in mind
to attacrt more UE’s make C2 higher.