27th August 2010 at 12:27
#64147
pix
Guest
hi ajay,
this is a parameter that controls the HO causes 14, 21 and 24 (= capture cause).
It is a very complex parameter to tune.
25 means = -110 +25 = -85dBm
35 means -75dBm
if -75dBm, the capture happens only when neighbour cell is better than -75dBm.
regards