Generic selectors
Exact matches only
Search in title
Search in content
Post Type Selectors

Reply To: Code COng, Power COng in 3G Node B Huawe

#63558
Paul
Guest

Dear Sunny,

Well, based on your statement, we can set in a nodeB with 2 different SFs, SF16 and SF32. Am I right?

But as I know, we can set only one SF. If we can set the SF more than 1, what specific indicator is that?

In Huawei, SF setting is like this :

List cell LDR algorithm parameters. Cell ID is 0.

LST CELLLDR: CELLID=0, LSTFORMAT=VERTICAL;

%%LST CELLLDR: CELLID=0, LSTFORMAT=VERTICAL;%%

RETCODE = 0 Execution succeeded.

List Cell LDR Algorithm Parameters

———————————-

Cell ID = 0

Cell name = cell1

DL LDR first action = CODE ADJUST

DL LDR second action = BE TRAFF RATE REDUCTION

DL LDR third action = INTER-FREQ LOAD HANDOVER

DL LDR fourth action = NO ACTION

DL LDR Fifth action = NO ACTION

DL LDR Sixth action = NO ACTION

DL LDR Seventh action = NO ACTION

DL LDR Eighth action = NO ACTION

DL LDR Ninth action = NO ACTION

DL LDR Tenth action = NO ACTION

DL LDR-BE rate reduction RAB number = 1

DL LDR un-ctrl RT Qos re-nego RAB num = 1

DL CS should be ho user number = 3

DL PS should be ho user number = 1

DL LDR-AMR rate reduction RAB number = 1

DL CS should not be ho user number = 3

DL PS should not be ho user number = 1

UL LDR first action = INTER-FREQ LOAD HANDOVER

UL LDR second action = BE TRAFF RATE REDUCTION

UL LDR third action = NO ACTION

UL LDR fourth action = NO ACTION

UL LDR Fifth action = NO ACTION

UL LDR Sixth action = NO ACTION

UL LDR Seventh action = NO ACTION

UL LDR Eighth action = NO ACTION

UL LDR-BE rate reduction RAB number = 1

UL LDR un-ctrl RT Qos re-nego RAB num = 1

UL CS should be ho user number = 3

UL PS should be ho user number = 1

UL LDR-AMR rate reduction RAB number = 1

UL CS ishould not be ho user number = 3

UL PS should not be ho user number = 1

UL HHO load space threshold[%] = 20

DL HHO load space threshold[%] = 20

UL HHO maximum bindwidths[bps] = 200000

DL HHO maximum bindwidths[bps] = 200000

MBMS decsend power rab threshold = 1

Cell LDR SF reserved threshold = SF8

LDR code priority indicator = FALSE

Max user number of code adjust = 1

Ul LDR Credit SF reserved threshold = SF8

Dl LDR Credit SF reserved threshold = SF8

(Number of results = 1)

— END

Thanks alot Sunny!,

Paul