22nd April 2010 at 06:22
#60532
Guest
Hi Sujeesh
Check the cause value
If the cause value in the Clear Command message is Protocol Error, refer to the related protocols.
If the cause value in the Clear Command message is Equipment Failure, check
the related BSC hardware:
1. Connection on the Ater interface
2.GEIUA in the GTCS
3. Check the timeout values of the related timers.
Br\\