Pan
Guest

Dear, Maria!
MS gets the T3212 value from System Info on BCCH.
When cell reselection is occured then t3212 shall be reloaded so that the new time to expiry will be:
“time to expiry in the old cell” mod (“T3212 value in the new cell”).
For example, if:
T3212 in the old cell = 360 min,
time to expiry in the old cell = 60 min.
T3212 in the new cell = 240 min min,
then the new time to expiry will be:
60 mod(240)= 60 min
and else,
if:
T3212 in the old cell = 720 min,
time to expiry in the old cell = 360 min.
T3212 in the new cell = 240 min min,
then the new time to expiry will be:
360 mod(240)= 120 min

similar manner is used for time to expiry reload in case of T3212 change in current cell.