22nd April 2009 at 05:52
#56795
forouzan
Guest
as my experience and also theorically non sync ho’s between the cells with the same clock decrease the chance of prompt ho between them but the main issue is when you have two cells in different sites which are sync together,will may cause lots of ho fail and call drop.maybe sometimes the a shouldn’t ho to b because b is most of the time congested and there are enough very good ho candidates around.however i prefer to use other solutions for such cases.