16th April 2009 at 06:22
#56792
Pix
Guest
Two cells are synchronized if they share the same clock, and the clock ze’re talking about is located within the BTS. In your situation, is there a radio parameter in cell 3 that force this cell to perform asynchronous HO rather than synchronous ones ?
Or perhaps the cell 3 is handled by another BTS (master BTS / slave BTS configuration) ?