Reply To: incoming HO problem

#55754
agp
Guest

Hi rcdece,
maybe you can try this setting on ADCE : from GSM/DCS >> indoor cell (PBGT = 63 (off), AUCL ~ 25/30, ACL = 3) .. ho will work only due to umbrella. from indoor >> gsm/dcs (PBGT = 63, AUCL = 63, ACL = 2) ho will depending on LDR/LUR only. Indoor cells is always “lowered” than DCS/GSM cells and DCS/GSM were “uppered” than Indoor cell.