pix
Guest

a ho is completed in about 20ms to 100ms. 20ms is a really fast value, which is measured when the MS is performing a synchronized HO (towards a cell synchronized with previous serving cell)

the loss of tch is not only due to FACCH, but also the time the MS takes to reconnect to the target cell (ho access, TA calculation, etc)