25th June 2007 at 07:34
#47912
Nabixm
Guest
There’s no LAU. The MS is performing a new attach without detach.
When asking the subscriber, he says that he has to reconnect because of “Deconnections”.
I don’t think there’s deconnections, but just maybe lack of received data. He should have felt that it’s lagging so he reconnect.
The question is :
If this is what happened, should we find a detach on the probe’s captures or is it normal to find a new attach without being detached ?