Dear Tomar,

Every thing is fine as i observed,so can u pls suggest which parameter to be changes for the below mentioned parameters….

Regards,
Promod

HANDOVER CONTROL PARAMETERS OF

ENABLE INTRA HO INTERF UL …… Y ENABLE INTRA HO INTERF DL …… Y
ENABLE PWRBUDGET HANDOVER …… Y ENABLE MS DISTANCE PROCESS ….. N
ENABLE SDCCH HANDOVER ………. N ENABLE UMBRELLA HANDOVER ……. N
ENABLE FAST AVE CALL SETUP ….. N ENABLE FAST AVE PC …………. N
ENABLE FAST AVE HO …………. N

MIN INT BETWEEN HO REQ …………. 05 s HO PERIOD UMBRELLA ……. 06
MIN INT BETWEEN UNSUCC HO ATTEMPT .. 03 s HO PERIOD PBGT ……….. 06

GSM PLMN PRIORISATION ………….. 0

AMH TRAFFIC CONTROL MCN …….. N AMH TRAFFIC CONTROL IUO …….. N
AMH TRHO PBGT MARGIN ……….. N

AVERAGING WINDOW SIZE ADJ CELL ….. 06 NUMBER OF ZERO RESULTS … 2
ALL ADJACENT CELLS AVERAGED …….. N

HO AVERAGING LEV DL WINDOW SIZE ………… 06 WEIGHTING …. 2
HO AVERAGING LEV UL WINDOW SIZE ………… 06 WEIGHTING …. 2
HO AVERAGING QUAL DL WINDOW SIZE ………… 01 WEIGHTING …. 2
HO AVERAGING QUAL UL WINDOW SIZE ………… 01 WEIGHTING …. 2

MS SPEED AVERAGING …………. 04

HO THRESHOLDS QUAL DL RX QUAL …… 3.2% – 6.4% PX .. 04 NX .. 04
HO THRESHOLDS QUAL UL RX QUAL …… 3.2% – 6.4% PX .. 04 NX .. 04

HO THRESHOLDS LEV DL RX LEVEL ………… -095 dBm PX .. 01 NX .. 01
HO THRESHOLDS LEV UL RX LEVEL ………… -095 dBm PX .. 01 NX .. 01
HO THRESHOLDS LEV UL FOR RAPID FIELD DROP . -110 dBm PX .. 00 (DISABLED)
ENABLE ENHANCED RAPID FIELD DROP ……….. DIS (DISABLED)
THRESHOLD DEEP DROPPING EDGE …………… 10 dB PX .. 02 NX .. 03
DEEP DROPPING EDGE MONITORING WINDOW ……. 2
MODIFIED AVERAGING WINDOW ……………… 2
MODIFIED NUMBER OF ZERO RESULTS ………… 1
ENHANCED RAPID FIELD DROP DURATION ……… 10 s
NON BCCH LAYER ACCESS THRESHOLD ………… -090 dBm
NON BCCH LAYER EXIT THRESHOLD ………….. -095 dBm PX .. 01 NX .. 01

HO THRESHOLDS INTERFERENCE DL RX LEVEL ….. -085 dBm PX .. 01 NX .. 01
HO THRESHOLDS INTERFERENCE UL RX LEVEL ….. -085 dBm PX .. 01 NX .. 01

MS DISTANCE AVERAGING PARAM WINDOW SIZE ….. 10
MS DISTANCE HO THRESHOLD PARAM MS RANGE MAX …. 63 PX .. 01 NX .. 01
MS DISTANCE HO THRESHOLD EXT. CELL MAX ……… 63
MS DISTANCE HO THRESHOLD EXT. CELL MIN ……… 02

USED C/I ESTIMATION METHOD …… NONE (ESTIMATION METHODS NOT IN USE)

LOWER C/I LIMIT 1 … 30 dB PRIORITY ADJ. STEP FOR BAND 1 … 3
LOWER C/I LIMIT 2 … 25 dB PRIORITY ADJ. STEP FOR BAND 2 … 1
LOWER C/I LIMIT 3 … 20 dB PRIORITY ADJ. STEP FOR BAND 3 … 0
LOWER C/I LIMIT 4 … 17 dB PRIORITY ADJ. STEP FOR BAND 4 … – 1
LOWER C/I LIMIT 5 … 13 dB PRIORITY ADJ. STEP FOR BAND 5 … – 2
LOWER C/I LIMIT 6 … 9 dB PRIORITY ADJ. STEP FOR BAND 6 … – 5
PRIORITY ADJ. STEP FOR BAND 7 … – 8

SUPER REUSE ESTIMATION METHOD …………. NONE (METH. NOT USED IN THIS CELL)
ENABLE INTER FRT HANDOVER …………….. DIS (DISABLED)
INTERFERING CELL AVERAGING WINDOW SIZE …. 10
INTERFERING CELL NUMBER OF ZERO RESULTS … 2
ALL INTERFERING CELLS AVERAGED ………… N
SUPER REUSE GOOD C/I THRESHOLD ………… 17 dB PX .. 08 NX .. 10
SUPER REUSE BAD C/I THRESHOLD ………… 10 dB PX .. 02 NX .. 06
MINIMUM BSIC DECODE TIME ……………… 10
ENABLE TCH ASS SUPER IUO ……………… 0
MINIMUM INTERVAL BETWEEN UNSUCC IUO HO …. 20 s
MINIMUM INTERVAL BETWEEN IUO HO REQ BQ …. 10 s
SUPER REUSE GOOD THRESHOLD RX LEVEL ……. -080 dBm PX .. 08 NX .. 10
SUPER REUSE BAD THRESHOLD RX LEVEL …….. -085 dBm PX .. 02 NX .. 06

LOWER SPEED LIMIT ……………………. 0 ( 0 km/h )
UPPER SPEED LIMIT ……………………. 0 ( 0 km/h )
MS SPEED THRESHOLD PX ……… 3 MS SPEED THRESHOLD NX ……… 6
MS SPEED DETECTION STATE ……………… 0

THRESHOLD DL RX QUAL AMR FR …………… 6.4% – 12.8%
THRESHOLD UL RX QUAL AMR FR …………… 6.4% – 12.8%
INTRA HO THRESHOLD RX QUAL AMR FR ……… 0.4% – 0.8%
THRESHOLD DL RX QUAL AMR HR …………… 6.4% – 12.8%
THRESHOLD UL RX QUAL AMR HR …………… 6.4% – 12.8%
INTRA HO THRESHOLD RX QUAL AMR HR ……… 1.6% – 3.2%