4th April 2006 at 15:16
#44706
Erkan Okay
Guest
Fabio and Rami,
Thanks a lot for your answers. So I’m going to have same HSN for co-site cells and different HSNs for neighbour sites.
There’s one more thing related to this discussion:
As far as I know “being synchronous” means TRXs on a site hop at the same exact time, and in general their frame numbers are identical.
Does the assignment of same HSN to cosite cells make them synchronous or are cosite cells already synchronous (or asynchronous) by their nature? Or is there a specific feature which makes cosite cells synchronous?
I admire your answering my questions. Thanks again.
Erkan