27th August 2014 at 09:51
#42733
GSM
Guest
One a subsciber B Hung UP, the MSC will send Suspend message instead Release, when sending SUSPEND the circuits will be mainted, when the MSC will whait until the Timer T6 expire in order to release the circuits, but if the user Pick Up again before T6 expire, the MSC will send resume message to continue the converstaion.