Reply To: TEST SYSTEM in AXE10

#36195
Wallis Dudhnath
Guest

Using AXE10’s Test-System comes with a government health warning. It can crash your system.

Below is an example of Test-System.

Below trace prints THE B-NUMBER & C-NUMBER FOR A PARTICULAR B-NUMBER

! THIS TRACE PRINTS THE B-NUMBER & C-NUMBER FOR A PARTICULAR B-NUMBER ;
! ;
! DR1-DR4 CONTAIN B-NUMBER DIGITS IN REVERSE ORDER ;
! ;
! WHERE – DR1=NOC+OSSP ;
! DR2=OVTK (1-4) ;
! DR3=OVTK (5) + DN(1-3) ;
! DR3=DN (4-7) ;
! ETC… ;
! ;
TESYS=1; !TERM IF RESTART!
ON IN SSFM1 H’95 H’A2; !ON IN SSFM1 SIGNALS!
ON IN DO:IF SNR=H’95 THEN; !IF B-NUMBER SIGNAL (SFPIDATA1BNR)!
IF DR4 MASK H’FFFF=H’4904; !IF OUR CALL (ENTER B-NUMBER HERE)!
CODE H’28; !WRITE REGISTER VALUE INTO TOM!
CODE H’0130; !LOCATION IN TOM OF H’ABCD BELOW!
CODE H’4001; !PR0 SSFM1 DIALOGUE POINTER!
P SWD; !PRINT B-NUMBER SIGNAL!
ELSE; !IF C-NUMBER SIGNAL (SFCRDATA1)!
IF PR0=H’ABCD; !IF OUR CALL!
CODE H’27; !WRITE CONSTANT VALUE INTO TOM!
CODE H’0130; !LOCATION IN TOM OF H’ABCD ABOVE!
CODE H’ABCD; !FLAG VALUE TO STOP TRACE!
P SWD; !PRINT C-NUMBER SIGNAL!
FI; !END IF!
;

! B-NUMBER & C-NUMBER RESULTS ;
! ;
! ON INSIG ;
! SSFM1 COMBSIG H’095 ON THL FROM SSFM2 WITH ;
! H’0000 0000, H’0000 0010, H’0000 1110, H’0000 5130, ;
! H’0000 5022, H’0000 4904, H’0000 0000, H’0000 4904, ;
! H’0000 4304 ;
! ;
! B-NUMBER= 0 111 03152 205 4094 ;
! DR0=LENGTH, DR1=NOC+OSSP, DR2=OVTK(1-4), DR3=OVTK(5)+DN(1-3) ETC.. ;
! ;
! ON INSIG ;
! SSFM1 COMBSIG H’0A2 ON THL FROM SSFM2 WITH ;
! H’0000 0000, H’0000 0012, H’0000 1200, H’0000 3011, ;
! H’0000 2251, H’0000 0450, H’0000 0049, H’0000 002A, ;
! H’0000 0001, H’0000 0002, H’0000 0001, H’0000 FFFF, ;
! H’0000 000A, H’0000 0000, H’0000 0046, H’0000 0000, ;
! H’0000 0000, H’0000 0000, H’0000 0000, H’0000 0000, ;
! H’0000 FC02 ;
! ;
! C-NUMBER= 0 0 2 111 03152 205 4094 ;
! DR0=LENGTH, DR1=NPI+P+LAD+TSSP(1), DR2=TSSP(2-3)+TVTK(1-2) ETC.. ;