31st August 2012 at 19:05
#68535
GSM2way
Guest
Hello Pix,
On BCCH Trx we have no active UL and DL PC even if PC enabled, maybe is it vendor dependent?
Anyway i am totally agree power control is not active during SD establishment, but after established SDCCH, can UL PC affect SD drop? how? am i missing something?
I will rollback in week.
Date SD Estab% SD Drop%
17.08.2012 99.14 0.63
18.08.2012 98.87 0.74
19.08.2012 99 0.81
20.08.2012 98.55 0.83
21.08.2012 98.98 0.76
22.08.2012 98.60 0.66
23.08.2012 98.77 0.72
UL PC Disabled (evening)
24.08.2012 98.83 0.9 many sites down related transmission
25.08.2012 99.06 0.65weekend
26.08.2012 98.93 0.7 weekend
27.08.2012 99.17 0.59
28.08.2012 99.20 0.58
29.08.2012 98.91 0.62
30.08.2012 99.07 0.61