20th March 2012 at 13:43
#66813
Pix
Guest
hi,
impacts other than voice quality:
– increase of traffic on AterMux and A interfaces
– increase of traffic load in the BSC (might impact the BSC dimensioning)
– need to tune HR and AMR-R thresholds
– need to buy HR licenses in order to declare TRXs as HR-capable (same goes for AMR-HR)
Those are not disadvantages… just “constraints”.
Cheers,
pix