18th February 2011 at 09:21
#65795
Guest
hi,
HR is good when TFO is enabled.
otherwise it is bad.
try it.
there is no operator in the world that is using AMR WB, so you’ll be the first ! rock n roll !
EN_TFO_OPT = Disable –> this avoids going back to FR when the call was started in HR, after a HO to a cell which is in lowload.
FORCE_TFO_VS_AMR = 0 –> DISABLE. It means that if a call is in AMR, TFO is disabled.
If FORCE_TFO_VS_AMR = Enable, then a call in AMR will stop AMR in order to enjoy TFO.
cheers
pix