5th March 2010 at 11:43
#61075
SHELDON
Guest
Hi Krish,
The total number of SDCCH seizure attempts in ERICSSON is given by: CCALLS+CCALLSSUB.
The number of successful SDCCH seizures is: CMSESTAB+CMSESTABSUB.
From these, you can calculate the number of failed attempts.
Regards,