Hi Broune,
As you have said your call drop is happening because of RLT timer expiry. Means your MS is not able to decode the Sacch frame. So your RLT counter will start and goes to 0 than after call drop happen.
I Think it can be because of either high interference or this cell can be stand alone cell.