Hi Alex
Pix already told much about MHT.I’m just adding some more:
I think you are using Nokia system.Check for MINHTT,PRDMHT&CS values.Improper settings may un-necessary yeild more alarms.Also,this alarm is causing TCH Drop only if it is accompanied by 7745 Alarm.Otherwise,intracell HO may be taking place or the Idle channel Interference is high on that particular channel/TRX