Reply To: adjacency type(ALCATEL B9)

#58534
pix
Guest

hi alphaRNO,

SD Drop and LU rate are caused by MS which are stuck in your cell.
Putitng a CRH=14dB means that the MS is stuck during 14dB in your cell before going to huawei… you see the problem ? I think you should decrease the CRH to 4dB or 8dB..

Then, in the Huawei cell, put a CRH to 4dB or 8dB.

Then put a TEMPORARY OFFSET = 12 dB in both cells
PENALTY TIME = 120s in both cells

Ensure the Cell Reselect Offset and the RX LEV ACCESS MIN are set to similar values in both cells (for example CRO=10dB and RXLEV ACCESS MIN = -110dBm).

That ought to give you a much cleaner environment to work with. You might still have SD Drops, but you should have less LU. If not, try to increase the Temp Offs and Pen Time step by step.

If nothing work, then ensure that you are not missing a better neighbour in the area (perhaps a far one)…

Finally, you can increase the T200 SDCCH and increase the Radiolink Timeout / Radiolink timeout BS. That might help the MS to recover the SD link before the BSC assumes there is a radop drop.
regards
pix