17th February 2009 at 13:52
#55815
RNP__
Guest
Hi Pix,
1st of all,Thanks a lot.
(For the 2nd case,)as I know,MS will try to decode the BSIC whose signal its getting.So if it gets signal for both Cell B(lets say -75 dBm) and Cell C (lets say -99 dBm) and lets say the serving cell A have level (-82 dBm) and if the MS try to HO from A to B is there any chance to wrong BSIC decode for B (instead of B its decoding the BSIC of C) so HO will fail/not happened?