12th April 2008 at 07:01
#51817
Guest
just assuming :
expiry of the authentication/ciphering phase between HLR and MS
lost messages on RSL link (Abis congested) or BSC board (processor congestion)
faulty board in the BTS (called “SUM” card in alcatel)
well, that’s all… i guess all other possibilities woul be counted in proper ericsson counters.