Hi all,
After frequency planning from BBH to FHS on Alcatel BSS we observed hight increase of HO cmd, multiply by 4 beetwen cell 1 and cell 2 (in fact all cell impacted in this FreqPlan).
HO cause are mainly ping-pong on level_UL and better cell, obviously due to interference.
Do you think the same HSN can be the root cause for this or is there something else ?
tx in advance.
Cell 1
======
TRX 0 :
——-
FREQ = 15
TRX 1 :
——-
FREQ = 46,41,36,31,32,42,47,48,43,38,33,34,39,44,49,50,45,40,35,30,29,28,27,26,37
FHS ID = 1
HSN = 25
MAIO = 10
Cell 2
======
TRX 0 :
——–
FREQ = 10
TRX 1 :
——-
FREQ = 46,41,36,31,32,42,47,48,43,38,33,34,39,44,49,50,45,40,35,30,29,28,27,26,37
FHS ID = 1
HSN = 25
MAIO = 20
TRX 2 :
——–
FREQ = 46,41,36,31,32,42,47,48,43,38,33,34,39,44,49,50,45,40,35,30,29,28,27,26,37
FHS ID = 1
HSN = 25
MAIO = 22