Generic selectors
Exact matches only
Search in title
Search in content
Post Type Selectors

Reply To: HO PARAMETER

#46507
Promod
Guest

2.ALSO WE HAVE A PROBLEM IN THE BSC BORDERS.THE STATS SHOWS THE 100% FAILURES EVEN THOUGH U DIFINE IN BOTHWAYS.

As i was having problem with INTER MSC and INTER BSC problem has been resolved after difining the LAC in the MSC level. So i thank for everybody giving the solution.

I would like to know what changes to be done in the below mentioned power control parameters due to the level HO problem.

POWER CTRL ENABLED ……… Y POWER CONTROL INTERVAL ….. 02 s
BS TX PWR MIN ….PEAK PWR – 30 dB BS TX PWR MAX ….PEAK PWR – 00 dB
BS TX PWR MAX1X00 PEAK PWR – 00 dB
POWER INCR STEP SIZE ……. 4 dB POWER RED STEP SIZE …….. 2 dB
POWER DECR LIMIT BAND 0 …. 38 dB POWER DECR LIMIT BAND 1 …. 38 dB
POWER DECR LIMIT BAND 2 …. 38 dB POWER DECR QUAL FACTOR ….. 1
ALA ENABLED ……………. N MIN INT BETWEEN ALA …….. 10 s
POWER LIMIT ALA ………… 6 dB

PC AVERAGING LEV DL WINDOW SIZE ………… 04 WEIGHTING …. 1
PC AVERAGING LEV UL WINDOW SIZE ………… 04 WEIGHTING …. 1
PC AVERAGING QUAL DL WINDOW SIZE ………… 01 WEIGHTING …. 1
PC AVERAGING QUAL UL WINDOW SIZE ………… 01 WEIGHTING …. 1

PC UPPER THRESHOLDS QUAL DL RX QUAL .. < 0.2% PX .. 16 NX .. 16 PC UPPER THRESHOLDS QUAL UL RX QUAL .. < 0.2% PX .. 16 NX .. 16 PC LOWER THRESHOLDS QUAL DL RX QUAL .. 0.8% - 1.6% PX .. 03 NX .. 04 PC LOWER THRESHOLDS QUAL UL RX QUAL .. 0.8% - 1.6% PX .. 03 NX .. 04 PC LOWER THRESHOLDS QUAL144 RX QUAL .. 0.8% - 1.6% PX .. 03 NX .. 04 PC UPPER THRESHOLDS LEV DL RX LEVEL .. - 68 dBm PX .. 01 NX .. 01 PC UPPER THRESHOLDS LEV UL RX LEVEL .. - 72 dBm PX .. 01 NX .. 01 PC LOWER THRESHOLDS LEV DL RX LEVEL .. - 80 dBm PX .. 01 NX .. 01 PC LOWER THRESHOLDS LEV UL RX LEVEL .. - 84 dBm PX .. 01 NX .. 01 PC UPPER THRESHOLDS DL RX QUAL AMR HR .. < 0.2% PC UPPER THRESHOLDS UL RX QUAL AMR HR .. < 0.2% PC LOWER THRESHOLDS DL RX QUAL AMR HR .. 0.8% - 1.6% PC LOWER THRESHOLDS UL RX QUAL AMR HR .. 0.8% - 1.6% Regards, Promod